Oxygen Analyzer Quantek Instruments

Berbagai product dari Quantek Instruments

 

      1. Oxygen Analyzer Model 901,
Spesifikasi :
Expected Lifetime (oxygen) 4-5 years
Oxygen Range 0.0 to 100%
Oxygen Sensitivity 0.1%
O2 Resolution 0.1%
Analog Output Not Available
Resolution 0.1% Oxygen
Accuracy : +/- 0.1% (below 10% oxygen).
Drift less than 0.4% per year
Oxygen Sensor Type Proprietary electrochemical cell, expected lifetime 4-5 years
Response Time 15 seconds to T95
O2 Sensor Lifetime 4-5 Years
O2 Sensor Body ABS Resin
Sample Connection Sample Probe
Sample Method Pump
Sample Pump Internal, draws ~5cc/sec, with 2-12 second adjustable timer (on side of unit)
Pump Timing 2-12 second adjustable pump time, potentiometer on side of analyzer
Minimum Sample Required 10cc
Sampling Assembly Probe with female luer connection for filter and needle, low volume PTFE tubing
Oxygen Calibration Controls SPAN adjustment, zero adjustment
Instrument Calibration Calibrates with room air; SPAN adjustment on side; ZERO adjustment on side
Exhaust port Vents to air
Power Supply Four “AA” NiMH rechargeable batteries; auto shut-off after 45 minutes idle. 100-240V (50-60Hz) Charger included, with US or international interchangeable plug adapter (upon request)
Backup Power Four “AA” alkaline batteries (not included)
Battery Operation Included
Input Voltage 100-240V, 50-60Hz
Battery Life 10-14 hours before recharging
Measures: O2, CO2 O2
Form Factor Portable
Size 8 x 4 x 1.8 in. (200 x 100 x 40 mm)
Weight 1 lb. (450 gms)
Warranty 2 years, parts and labor
Standards CE, RoHS
Included Consumables 200 foam septas, 2 luer fit needles, 2 particulate filters, 2 liquid block filters
Included Documentation Owners manual (includes operating instructions with detailed calibration instructions, calibration certficate, precautions), NIST calibration certificate
Origin of Goods Our products are manufactured in the U.S.A.
Products by Gas Oxygen
Products by Applications Headspace / Package
    2. Oxygen Analyzer Model 905,
Spesifikasi :
Expected Lifetime (oxygen) 4-5 years
Oxygen Range 0.0 to 100%
Oxygen Sensitivity 0.1% (or optional 0.01%)
O2 Resolution 0.1% (or optional 0.01%)
Analog Output Not Available
Resolution 0.1% (or optional 0.01%)
Accuracy : +/- 0.1% (for oxygen levels below 10%)
Drift less than 0.4% per year
Oxygen Sensor Type Proprietary electrochemical cell, expected lifetime 4-5 years
Response Time 15 seconds to T95
O2 Sensor Lifetime 4-5 Years
O2 Sensor Body ABS Resin
Sample Connection Sample Probe
Sample Method Pump
Sample Pump Internal, draws ~5cc/sec, with 2-12 second adjustable timer (on back of unit)
Pump Timing 2-12 second adjustable pump time, potentiometer on side of analyzer
Minimum Sample Required 10cc
Sampling Assembly Probe with female luer connection for filter and needle, low volume PTFE tubing
Oxygen Calibration Controls SPAN adjustment, zero adjustment
Instrument Calibration Calibrates with room air; SPAN adjustment on back; ZERO adjustment on back
Exhaust port Vents to air
Power Supply 100-240V (50-60Hz) Charger included, with US or international interchangeable plug adapter (upon request)
Backup Power Optional 12V internal battery pack
Battery Operation Optional
Input Voltage 100-240V, 50-60Hz
Battery Life 8-12 hours before recharging
Measures: O2, CO2 O2
Form Factor Benchtop
Size 9.8in x 4in x 10in. (249 x 102 x 254 mm)
Weight 8 lb. (3.6 Kg)
Warranty 2 years, parts and labor
Standards CE, RoHS
Included Consumables 200 foam septas, 2 luer fit needles, 2 particulate filters, 2 liquid block filters
Options Battery, 0.01% resolution
Included Documentation Owners manual (includes operating instructions with detailed calibration instructions, calibration certficate, precautions), NIST calibration certificate
Origin of Goods Our products are manufactured in the U.S.A.
Products by Gas Oxygen
Products by Applications Headspace / Package
3. Oxygen Analyzer Model 201,
Spesifikasi :
Expected Lifetime (oxygen) 4-5 years
Oxygen Range 0.0 to 100%
Oxygen Sensitivity 0.1%
O2 Resolution 0.1%
Analog Output Not Available
Resolution 0.1% Oxygen
Accuracy +/- 0.1% (from 0-20%), +/- 0.2% (from 20% to 50%), +/- 0.5% (from 50% to 100%)
Drift less than 0.4% per year
Oxygen Sensor Type Proprietary Electochemical
Response Time 15 seconds to T95
O2 Sensor Lifetime 4-5 Years
O2 Sensor Body ABS Resin
Sample Connection 1/4 inch plastic slip on
Sample Method Flowing gas required
Sample Pump Not Available
Pump Timing Not Available
Sampling Port 1/4 inch plastic slip on
Minimum Sample Required 10cc
Sampling Assembly Not Available
Oxygen Calibration Controls SPAN adjustment, zero adjustment
Instrument Calibration Calibrates with room air; SPAN keypad adjustment on front panel
Exhaust port Vents to air (T fitting included for recapture of sample gas)
Power Supply Four “AA” alkaline batteries; (optional) 5V power supply
Backup Power Optional 5V power supply
Battery Operation Included
Input Voltage 100-240V, 50-60Hz
Battery Life 2000 hours
Measures: O2, CO2 O2
Form Factor Portable
Size 90 x 40 x 140 mm
Weight 1 lb. (450 gms)
Warranty 2 years, parts and labor
Standards CE, RoHS
Included Consumables Filters, tubing, T-fitting
Options None
Included Documentation Owners manual (includes operating instructions with detailed calibration instructions, calibration certficate, precautions), NIST calibration certificate
Origin of Goods Our goods are manufactured in the U.S.A.
Products by Gas Oxygen

 

More Information :
WA : +62 856-4005-2560 (Indira) /+62 812-1626-5523 (Anan)
Email : marketing@asnindo.co.id
Website : www.asnindo.co.id

Tinggalkan Komentar

Alamat email Anda tidak akan dipublikasikan. Ruas yang wajib ditandai *

Reach us on WhatsApp
1